Determinazione dell'azoto nei peptidi attivi farmaceutici
La determinazione dell'azoto e delle proteine totali nei prodotti farmaceutici è descritta nei capitoli della Farmacopea Europea (Ph.Eur.) 2.5.9 e 2.5.33, metodo 7 [1, 2]. Nella farmacopea degli Stati Uniti (USP), la determinazione dell'azoto è descritta nel capitolo 461 [3]. Qui vengono specificate diverse tecniche di titolazione. La Ph.Eur. utilizza la retro-titolazione ed utilizza il rosso metile come indicatore, mentre l'USP utilizza la titolazione diretta potenziometrica, con l'utilizzo dell'acido borico.
The wet digestion is used to remove all carbonous material from the sample. The remaining inorganic content can be weighed out, resulting in the sulfated ash, or then be used for further elemental analysis. The digestion is performed using concentrated sulfuric acid while heating the mixture. The heat is ramped automatically using the BUCHI Wet Digester B-440. Once the sulfuric acid has digested the sample and is evaporated, the sample is eventually ashed in a muffle oven to remove any remaining organic material.
Guida alle applicazioni Syncore®
Scoprite gli aspetti importanti per l’evaporazione di solventi specifici, miscele di solventi e per la concentrazione di un campione a un volume predefinito. Questo manuale contribuirà a semplificare il vostro processo grazie ad applicazioni di esempio, elenchi di controllo, suggerimenti, regole, tabelle e test.
Achieve higher distillation efficiency when using a rotary evaporator by reading on the impact of immersion angle.
The evaporation rate of a rotary evaporator depends to a large extend on the immersion angle of the evaporating flask. The flatter the immersion angle, the higher the evaporation rate. This is, among other reasons, due to the fact that a flat immersion angle increases turbulence inside the evaporating flask, hence accelerating the evaporation. However, with a flatter immersion angle the evaporating flask cannot be as deeply immersed in the heating bath medium compared with a steep immersion angle. This can be an issue especially working with smaller evaporating flasks. Generally speaking, a 40 degrees immersion angle leads to a maximum efficiency rate without restriction in handling or risking losing parts of the sample due to over spilling and bumping into the receiving flask.
Achieve higher distillation efficiency when using a rotary evaporator by reading on the impact of flask size.
Generally, the larger the evaporating flask the greater is the evaporation rate. This is due to the greater turbulence inside a larger flask, enlarging the active surface and leading to a higher evaporation output. On the other hand, smaller flasks are advantageous when the residue needs to be collected for further quantitative analyses. Moreover, larger flasks generally allow easier handling.