SyncorePlus Application Guide
This application guide describes important aspects of the evaporation of solvents and the concentration of a sample to a predefined volume using the SyncorePlus. Guidelines for the evaporation of your specific solvent and solvent mixtures are presented. They will help you to streamline your own process with sample applications, checklists, hints, rules, tables, and tests.
Tips Pure untuk kromatografi lebih aman dan ramah lingkungan
Selama proses kromatografi, kesehatan para ahli kimia merupakan prioritas utama. Sampel itu sendiri memerlukan perhatian yang memadai. Dampak lingkungan tidak boleh dilupakan.
Temukan tindakan mana yang dapat dengan mudah diadopsi untuk melindungi pengguna, sampel, dan lingkungannya secara memadai.
Baca tentang tips Pure untuk kromatografi yang lebih aman dan ramah lingkungan.

Your Evaporation Guide - Evaporating flask size
Achieve higher distillation efficiency when using a rotary evaporator by reading on the impact of flask size.
Generally, the larger the evaporating flask the greater is the evaporation rate. This is due to the greater turbulence inside a larger flask, enlarging the active surface and leading to a higher evaporation output. On the other hand, smaller flasks are advantageous when the residue needs to be collected for further quantitative analyses. Moreover, larger flasks generally allow easier handling.
Your Evaporation Guide – Rotation speed
Achieve higher distillation efficiency when using a rotary evaporator by reading on the impact of rotation speed.
The evaporation rate of a rotary evaporator is greater than that of static distillation apparatus. Moreover, the evaporation rate increases with higher rotation speed. This is, among other factors, due to the greater surface area inside the evaporating flask at one given time. Especially significant is the dissipation at lower rotation speeds. For instance an increase in speed above 200 rpm has a relatively low influence on the evaporation output. A rotation speed above 300 rpm can result in mechanical problems, vibrations and spillage from the heating bath. Thus, considering the advantages and disadvantages of different rotation speeds, the optimum rotation speed is around 250 to 280 rpm.
Your Evaporation Guide – Thickness of evaporating flask
Achieve higher distillation efficiency when using a rotary evaporator by reading on the impact of thickness of flask.
The evaporation rate is noticeably greater if the evaporating flask’s glass walls are thinner. The simple reason is that thinner glass allows better heat transmission from the heating bath through the glass of the evaporating flask to the solvent. Generally speaking, the glass wall thickness should be selected to be as thin as possible, while still being robust enough to prevent breakages of the evaporating flask even at very low pressures. Concerning both these issues, the optimum thickness for a 1 L evaporating flask is between 1.5 and 2.0 mm.
Chromapedia: panduan lengkap
Chromapedia lengkap memberi Anda pengetahuan penting untuk mengembangkan dan melakukan metode kromatografi flash dan HPLC preparasi yang optimal. Andalkan teori yang tepat dan penjelasan yang jelas dari semua bagian proses kromatografi. Gunakan dasar-dasar kromatografi untuk mengembangkan metode Anda sendiri dengan bahan habis pakai, metode pendeteksian, fase diam dan fase gerak yang ideal untuk penerapan Anda.
Your Evaporation Guide – Temperature difference
Achieve higher distillation efficiency when using a rotary evaporator by reading on the impact of temperature differences.
There is a direct relationship between the heating bath temperature and the evaporation rate. The more energy applied to the evaporation side, and at the same time removed from the condensation side, the more efficient is the distillation. Furthermore, sufficient cooling as well as an appropriate and stable under pressure are crucial for efficient distillation. On the other hand, the consumption of electrical energy is comparatively greater at higher temperatures. Moreover, some samples are thermo-sensitive, thus exacerbating the circumstances. Therefore the respective parameters have to be fine-tuned to the individual sample and application. The “Delta 20 Rule” is a guideline to compromise between high evaporation output and energy usage. For instance, using the 10/30/50 parameters is appropriate for the evaporation process in order to bring in and to carry off the accumulated energy efficiently.