Buchi Logo
  • Fields of Activities
    • Evaporation Solutions
      • Rotavapor® Systems
      • Rotavapor® R-210/R-215
      • Rotavapor® R II
      • Rotavapor® R-3
      • Vacuum Solutions
      • Vacuum Pump V-700
      • Vacuum Pump V-710
      • Vacuum Controller V-850/V-855
      • Vacuum Modules EasyVac
      • Vacuum Modules LabVac
      • Recirculation Chiller
      • Glass Oven B-585 Kugelrohr
      • Glass Oven B-585 Drying
    • Industrial Evaporation
      • Rotavapor R-220 SE
      • Rotavapor R-220 EX
      • Rotavapor R-250
      • Rotavapor R-250 EX
      • Chiller for R-220 SE
    • Spray Drying & Encapsulation
      • Nano Spray Dryer B-90
      • Mini Spray Dryer B-290
      • Inert Loop B-295
      • Dehumidifier B-296
      • Encapsulator B-390 / B-395 Pro
    • Melting Point
      • Melting Point M-560
      • Melting Point M-565
      • Sample Loader M-569
    • Parallel Evaporation
      • Multivapor P-6/P-12
      • Syncore Polyvap
      • Syncore Analyst
      • SPE and Evaporation
    • Flash Chromatography
      • Manual Controlled
      • Computer Controlled
      • Applications
      • Systems
    • Extraction Solutions
      • Classical Extraction
      • Pressurized Solvent Extraction
      • Sample Preparation
    • Kjeldahl Solutions
      • Digestion
      • Distillation
      • Kjeldahl Tablets
    • NIRSolutions
      • NIRFlex
      • NIRMaster
      • NIRWare
      • NIRCal
      • Online
      • NIR Applications
  • Applications
    • Search
    • Parallel Evaporation
    • NIR Applications
    • Spray Dryer Application Finder
    • Flash Chromatography
    • Kjeldahl
      • Application Notes Order Area
    • Extraction
      • Application Notes Order Area
    • Melting Point
    • best@buchi
    • Literature
    • Application Support
  • Service & Support
    • Technical Support
    • Maintenance Contracts
    • Training@buchi
    • Downloads (Manuals etc)
    • Find your local Service Center
    • Individual Consulting
    • Contact
    • Two-Year Warranty Registration
  • About BUCHI
    • Company Profile
    • News
    • Events
    • Worldwide
      • Africa
      • Asia
      • Europe
      • Latin America
      • Middle East
      • North America
      • Oceania
      • All other countries
    • Affiliated Companies
    • Careers
    • Company & History Movies
    • Management
    • Find us
    • Awards
  • Customer Statements
    • Case Studies
    • Interviews
      • Interview details
    • Videos Customer Statements

Your basket

Home > Fields of Activities > Spray Drying & Encapsulation > Products > Mini Spray Dryer B-290 > FAQ

Mini Spray Dryer B-290

With over 30 years of experience, BUCHI is the expert in both, labscale spray drying and spray chilling with the innovative Mini Spray Dryer B-290 and Nano Spray Dryer B-90 systems and it’s full compliment of accessories.



Get the Facts

 
  • Features
  • Accessories
  • Spare Parts
  • FAQ
  • Specifications
  • Applications
  • Videos

Bio-hazardous samples in the Mini Spray Dryer

I want to spray biologically hazardous samples. How can I effectively protect myself and the environment?
The system has to be installed in a fume hood. To eliminate any possible contamination during operation, the front window is closed and the system is run with the Remote Control Panel. A sterile filter (e.g. from PALL, please ask for further specification) eliminates any outlet of hazardous samples.

Collecting vessel

I want to spray a lot of a product. Is a bigger collecting vessel available?
Yes, we have made a 1,5 litre collection vessel with beaker flask connection.

Cyclone

I would like to spray a very expensive product , which opportunity do I have?
For this purpose, BUCHI is offering a smaller high-performance cyclone. Small samples as little as 20 ml can be processed with a high recovery rate.

Dichloromethane

Is it possible to spray with Dichloromethane as solvent?
Yes it is, with the Inert Loop B-295 at -20°C it is possible to condense approx. 70% of the solvent. An additional Cold Trap in the exhaust tube is recommended to increase the recovery rate.

Filter material

Which filter material shall I normally use?
If the filter is only needed to clean the exhaust air, we recommend the deep-filter in Polyester. This filter has a very good separation rate and is relatively cheap. For all others, who are interested in a certain recovery from the filter, the PTFE membrane type is the right choice.

Glass breakage of Cylinder

During cleaning of the cylinder, the glass part may break. How can I prevent this?
We recommend to put a little piece of rubber tube around the outlet connection of the separation vessel. This dampens possible hits and thus glass breakage can be limited.

Glass Compatibility

Can I use my old glass parts of the B-191?
The cyclone with the glass elbow and also the separation flask remain the same. The cylinder is not compatible.

Nozzle Compatibility

Is the new nozzle also compatible for the B-191?
Yes, the new nozzle is compatible even its length is bigger. So for an exchange of nozzles, the new nozzle is recommended. Please contact your local sales representative with order code 44698.

Organic solvents

Do we have the possibility to spray with organic solvents?
Yes, with the Mini Spray Dryer B-290 and the Inert Loop B-295 it is possible to spray with organic solvents without risk of explosion, because the system works under inert condition.

The Mini Spray Dryer B-191 is designed for aqueous solutions only. If flammable solvents are used, it can cause an explosive mixture. Therefore, BUCHI neglects any responsibility if organic solvents are used.

Outlet Temperature

The Outlet Temperature drops during the Spray Drying Process. What is the matter?
A typical reason is that the outlet filter is blocked. Therefore, the air volume is lower and thus the energy limited, leading to a lower outlet temperature.

Particle size

What is the range of the particle size?
The range of particle size goes from 0.5 to 30 micrometer. The lower limitation is given by the separation of the cyclone: smaller particles can not be separated anymore and are going into the filter.

Plastic+Glass

Can I order the glass assembly in PLASTIC+GLASS ?
Of course, this can be made as a special version. The temperature of the inlet gas stream is limited to 120°C.

Spray cylinders

 If I change the glass cylinder, how does it affect the spray drying results?
With the vertical outlet cylinder, the heat losses are a little smaller what leads to a higher outlet temperature. Therefore, pump rate can be increased to obtain the same conditions compared to the other cylinder.

  • Top of page
  • Privacy
  • Sitemap
  • Partnernet
  • Terms
  • Webmaster
  • Print
  • © 2012 BÜCHI Labortechnik AG
BÜCHI Labortechnik AG Logo BÜCHI Labortechnik AG
Meierseggstrasse 40
Postfach
CH-9230 Flawil 1
Switzerland

www.buchi.com
buchi@buchi.com
Tel: +41 71 394 63 63
Fax: +41 71 394 64 64

© 2008 BÜCHI Labortechnik AG    
last modified: 12 September 2011
  • Global Site
  • Worldwide

Contact BUCHI

Contact BUCHI
  • Order a print brochure
Operation manuals of discontinued products

Product information

  • Mini Spray Dryer B-290 (pdf, 492.34k)
  • Encapsulator B-390 / B-395 Pro (pdf, 940.64k)
  • Nano Spray Dryer B-90 (pdf, 1.16Mb)
  • Products & Solutions EN (pdf, 1.33Mb)
  • Training Papers Spray Drying (pdf, 715.28k)
  • Quick Operation Guide (pdf, 62.14k)
  • Quick Operation Guide Spray Chilling Accessory (pdf, 436.12k)
  • Mini Spray Dryer B-290 System Configuration (pdf, 156.34k)
  • Process parameters flyer (pdf, 988.79k)
  • All Downloads

Buchi community *

  • Operation Manual Mini Spray Dryer B-290 (pdf, 1.74Mb)
  • Betriebsanleitung Mini Spray Dryer B-290 (pdf, 1.94Mb)
  • Mode d'emploi Atomiseur de séchage B-290 (pdf, 1.95Mb)
  • Manual de instrucciones Mini Spray Dryer B-290 (pdf, 1.95Mb)
  • Istruzioni per l'uso Mini Spray Dryer B-290 (pdf, 1.94Mb)

* free registration required

Your account

Login


Forgot your password?Newsletter ArchiveSubscribe to our Newsletter