Buchi Logo
  • Fields of Activities
    • Evaporation Solutions
      • Rotavapor® Systems
      • Rotavapor® R-210/R-215
      • Rotavapor® R II
      • Rotavapor® R-3
      • Vacuum Solutions
      • Vacuum Pump V-700
      • Vacuum Pump V-710
      • Vacuum Controller V-850/V-855
      • Vacuum Modules EasyVac
      • Vacuum Modules LabVac
      • Recirculation Chiller
      • Glass Oven B-585 Kugelrohr
      • Glass Oven B-585 Drying
    • Industrial Evaporation
      • Rotavapor R-220 SE
      • Rotavapor R-220 EX
      • Rotavapor R-250
      • Rotavapor R-250 EX
      • Chiller for R-220 SE
    • Spray Drying & Encapsulation
      • Nano Spray Dryer B-90
      • Mini Spray Dryer B-290
      • Inert Loop B-295
      • Dehumidifier B-296
      • Encapsulator B-390 / B-395 Pro
    • Melting Point
      • Melting Point M-560
      • Melting Point M-565
      • Sample Loader M-569
    • Parallel Evaporation
      • Multivapor P-6/P-12
      • Syncore Polyvap
      • Syncore Analyst
      • SPE and Evaporation
    • Flash Chromatography
      • Manual Controlled
      • Computer Controlled
      • Applications
      • Systems
    • Extraction Solutions
      • Classical Extraction
      • Pressurized Solvent Extraction
      • Sample Preparation
    • Kjeldahl Solutions
      • Digestion
      • Distillation
      • Kjeldahl Tablets
    • NIRSolutions
      • NIRFlex
      • NIRMaster
      • NIRWare
      • NIRCal
      • Online
      • NIR Applications
  • Applications
    • Search
    • Parallel Evaporation
    • NIR Applications
    • Spray Dryer Application Finder
    • Flash Chromatography
    • Kjeldahl
      • Application Notes Order Area
    • Extraction
      • Application Notes Order Area
    • Melting Point
    • best@buchi
    • Literature
    • Application Support
  • Service & Support
    • Technical Support
    • Maintenance Contracts
    • Training@buchi
    • Downloads (Manuals etc)
    • Find your local Service Center
    • Individual Consulting
    • Contact
    • Two-Year Warranty Registration
  • About BUCHI
    • Company Profile
    • News
    • Events
    • Worldwide
      • Africa
      • Asia
      • Europe
      • Latin America
      • Middle East
      • North America
      • Oceania
      • All other countries
    • Affiliated Companies
    • Careers
    • Company & History Movies
    • Management
    • Find us
    • Awards
  • Customer Statements
    • Case Studies
    • Interviews
      • Interview details
    • Videos Customer Statements

Your basket

Home > Fields of Activities > NIRSolutions > Products > NIRFlex > Good Reasons

NIRFlex N-500

 
  • Measurement Cells
  • Advantages
  • Good Reasons
  • Interferometer
  • Facts

Good Reasons for applying FT-NIR Spectroscopy


For years, FT-NIR spectroscopy has proven to be the ideal tool for routine checks in the pharmaceutical and chemical industries as well as in food and feed processing plants. Hundreds of applications have already been successfully solved using NIRSolutions.

Advantages of NIR Spectroscopy over Traditional Wet Chemistry

  • Versatile - simultaneous measurement of several parameters
  • Fast - measurement results obtained within seconds
  • Easy - extremely user-friendly routine
  • Economical - reduces operating expenses
  • Environmentally beneficial - no chemical waste
  • Safe - no chemical reactions
  • Efficient - more analyses from a batch per time unit

Advantages of FT-NIR Technology over Traditional NIR Instruments

  • Information content - Classical filter devices operate with just a few selected wavelengths. The NIRFlex N-500, on the other hand, covers a spectral range from 1000 to 2500 nm, recorded with optimal resolution for the analysis of your samples.
  • Fast - All frequencies are measured simultaneously and strike the detector at the same moment. The advantage: high optical throughput, improved signal- to-noise ratio.
  • High precision and reproducibility - Wavelength accuracy is guaranteed by sampling the interferometer using a HeNe laser signal. This ensures calibration transfer between instruments.
  • Unlimited range of applications - A wide variety of samples can be checked with the same instrument.
  • Top of page
  • Privacy
  • Sitemap
  • Partnernet
  • Terms
  • Webmaster
  • Print
  • © 2012 BÜCHI Labortechnik AG
BÜCHI Labortechnik AG Logo BÜCHI Labortechnik AG
Meierseggstrasse 40
Postfach
CH-9230 Flawil 1
Switzerland

www.buchi.com
buchi@buchi.com
Tel: +41 71 394 63 63
Fax: +41 71 394 64 64

© 2008 BÜCHI Labortechnik AG    
last modified: 15 December 2011
  • Global Site
  • Worldwide

Contact BUCHI

Contact BUCHI
  • Order a print brochure
Operation manuals of discontinued products

Product information

  • Brochures NIRFlex N-500 (pdf, 2.32Mb)
  • Products & Solutions EN (pdf, 1.33Mb)
  • NIRSolutions (pdf, 1.01Mb)
  • All Downloads

Buchi community *

  • Betriebsanleitung NIRFlex N-500 (pdf, 2.99Mb)
  • Manual de instrucciones NIRFlex N-500 (pdf, 2.99Mb)
  • Operation Manual NIRFlex N-500 (pdf, 7.17Mb)
  • Manuel d'instrucions NIRFlex N-500 (pdf, 2.99Mb)
  • Istruzioni per l'uso NIRFlex N-500 (pdf, 2.99Mb)

* free registration required

Your account

Login


Forgot your password?Newsletter ArchiveSubscribe to our Newsletter