Buchi Logo
  • Fields of Activities
    • Evaporation Solutions
      • Rotavapor® Systems
      • Rotavapor® R-210/R-215
      • Rotavapor® R II
      • Rotavapor® R-3
      • Vacuum Solutions
      • Vacuum Pump V-700
      • Vacuum Pump V-710
      • Vacuum Controller V-850/V-855
      • Vacuum Modules EasyVac
      • Vacuum Modules LabVac
      • Recirculation Chiller
      • Glass Oven B-585 Kugelrohr
      • Glass Oven B-585 Drying
    • Industrial Evaporation
      • Rotavapor R-220 SE
      • Rotavapor R-220 EX
      • Rotavapor R-250
      • Rotavapor R-250 EX
      • Chiller for R-220 SE
    • Spray Drying & Encapsulation
      • Nano Spray Dryer B-90
      • Mini Spray Dryer B-290
      • Inert Loop B-295
      • Dehumidifier B-296
      • Encapsulator B-390 / B-395 Pro
    • Melting Point
      • Melting Point M-560
      • Melting Point M-565
      • Sample Loader M-569
    • Parallel Evaporation
      • Multivapor P-6/P-12
      • Syncore Polyvap
      • Syncore Analyst
      • SPE and Evaporation
    • Flash Chromatography
      • Manual Controlled
      • Computer Controlled
      • Applications
      • Systems
    • Extraction Solutions
      • Classical Extraction
      • Pressurized Solvent Extraction
      • Sample Preparation
    • Kjeldahl Solutions
      • Digestion
      • Distillation
      • Kjeldahl Tablets
    • NIRSolutions
      • NIRFlex
      • NIRMaster
      • NIRWare
      • NIRCal
      • Online
      • NIR Applications
  • Applications
    • Search
    • Parallel Evaporation
    • NIR Applications
    • Spray Dryer Application Finder
    • Flash Chromatography
    • Kjeldahl
      • Application Notes Order Area
    • Extraction
      • Application Notes Order Area
    • Melting Point
    • best@buchi
    • Literature
    • Application Support
  • Service & Support
    • Technical Support
    • Maintenance Contracts
    • Training@buchi
    • Downloads (Manuals etc)
    • Find your local Service Center
    • Individual Consulting
    • Contact
    • Two-Year Warranty Registration
  • About BUCHI
    • Company Profile
    • News
    • Events
    • Worldwide
      • Africa
      • Asia
      • Europe
      • Latin America
      • Middle East
      • North America
      • Oceania
      • All other countries
    • Affiliated Companies
    • Careers
    • Company & History Movies
    • Management
    • Find us
    • Awards
  • Customer Statements
    • Case Studies
    • Interviews
      • Interview details
    • Videos Customer Statements

Your basket

Home > Fields of Activities > Industrial Evaporation > Products > Chiller for R-220 SE > FAQ

Recirculating Chiller F-125

F-125 – a powerful industrial chiller with a cooling capacity of 2500W at 15°C and an integrated trolley for use with the Rotavapor®
R-220 SE industrial rotary evaporator

 
  • Features
  • Chiller models
  • Accessories
  • Spare Parts
  • Specifications
  • FAQ

Frequently asked questions:


Refrigerant

What is R134a?

R-134a is 1,1,1,2-Tetrafluoroethane. this is a haloalcane refrigerant with thermodynamic properties similar to R-12 (dichlorodifluoromethane), but with less ozone depletion potential.

Cooling medium, coolant

What coolant is recomended?

If the mixture of the coolant is not correct, it may freeze in the chiller and block or destroy the pump. Therefore we recommend a mixture of ethylene glycol and water 30/70 (%V). This mixture has a freezing point of -14°C. As the F-100 has a fix temperature of 10°C also water is OK.

More than one Rotavapor on a chiller?

Can the recirculating chiller be controlled by more than one vacuum controller?


The recirculating chiller has only one connection RJ45 for a vacuum controller. If more than one Rotavapor is cooled by one chiller, the chiller has to be operated by its internal control panel.

Heat emissions

How much heat is generated by the chiller?

The compressor in the chiller generate a lot of heat. The is blown out of the unit by a fan. The produced heat depends on the cooling capacity of the chiller. The heat capacities are:
- F-100       max. 300W
- F-105       max. 300W
- F-108       max. 500W
- F-114       max. 1000W
- F-125       max. 1800W
In the standby mode the compressor and also the circulating pump is turned off and does not generate any heat emissions.

  • Top of page
  • Privacy
  • Sitemap
  • Partnernet
  • Terms
  • Webmaster
  • Print
  • © 2012 BÜCHI Labortechnik AG
BÜCHI Labortechnik AG Logo BÜCHI Labortechnik AG
Meierseggstrasse 40
Postfach
CH-9230 Flawil 1
Switzerland

www.buchi.com
buchi@buchi.com
Tel: +41 71 394 63 63
Fax: +41 71 394 64 64

© 2008 BÜCHI Labortechnik AG    
last modified: 07 March 2011
  • Global Site
  • Worldwide

Contact BUCHI

Contact BUCHI
  • Order a print brochure
Operation manuals of discontinued products

Product information

  • Brochure Recirculation Chiller (pdf, 432.14k)
  • Products & Solutions EN (pdf, 1.33Mb)
  • Original Glass-Ware (pdf, 3.4Mb)
  • Training Papers "Safety against explosion accidents" (pdf, 466.89k)
  • All Downloads

Buchi community *

  • Manuel d'instructions Refroidisseur à circulation F-125 (pdf, 3.46Mb)
  • Manual de instrucciones Recirculador F-125 (pdf, 3.47Mb)
  • Istruzioni per l'uso Recirculating Chiller F-125 (pdf, 3.46Mb)
  • Betriebsanleitung Umlaufkühler F-125 (pdf, 3.47Mb)
  • Operation Manual Recirculating Chiller F-125 (pdf, 3.46Mb)

* free registration required